UV Steriliser
LGND Eclipse Internal UV‑C 3W / 5W

Integrated UV-C sterilisation and water circulation

Available in 3W and 5W models

Helps eliminate green water algae

Reduces free-floating bacteria and microorganisms

Price range: £ 52.99 through £ 58.99 (incl. VAT)

  • EUR: 73.76€ - 82.10€

- +
Overview ›

The LGND Eclipse Internal UV-C™ Series combines ultraviolet water sterilisation and efficient water circulation in a compact, fully submersible design. Available in 3W and 5W models, the Eclipse Internal UV-C™ helps reduce free-floating algae and microorganisms, improving water clarity and supporting a healthier aquatic environment.

Its integrated water pump circulates aquarium water through an enclosed UV-C chamber, providing effective treatment without exposing fish or aquatic plants directly to ultraviolet radiation. The adjustable water flow and built-in timer controller allow convenient operation, while the compact design makes installation and maintenance simple.

Designed for freshwater aquariums, the Eclipse Internal UV-C™ delivers reliable performance with minimal visual impact.

Key Features ›
  • Integrated UV-C sterilisation and water circulation
  • Available in 3W and 5W models
  • Helps eliminate green water algae
  • Reduces free-floating bacteria and microorganisms
  • Fully submersible design – IPX8
  • Adjustable water flow
  • Built-in timer controller
  • 3H / 6H / 12H / 24H operating modes
  • Compact and discreet installation
  • Energy-efficient operation
  • Easy installation and cleaning
  • Suitable for freshwater aquariums
Technical Specifications ›
Product SeriesLGND Eclipse Internal UV-C™
UV-C Lamp Power3W
Input Voltage220–240V AC
Frequency50Hz
InstallationInternal / Submersible
Maximum Flow Rate500 L/h
Flow AdjustmentAdjustable
Maximum Aquarium Volume200 L
Waterproof RatingIPX8
Timer Settings3H / 6H / 12H / 24H
Operating Cycle24-hour repeat
Water TypeFreshwater
UV-C LampReplaceable
Product SeriesLGND Eclipse Internal UV-C™
UV-C Lamp Power5W
Input Voltage220–240V AC
Frequency50Hz
InstallationInternal / Submersible
Maximum Flow Rate500 L/h
Flow AdjustmentAdjustable
Maximum Aquarium Volume350 L
Waterproof RatingIPX8
Timer Settings3H / 6H / 12H / 24H
Operating Cycle24-hour repeat
Power Cable1.5 m
Water TypeFreshwater
UV-C LampReplaceable
UV Lamp Replacement ›
  • Step 1: Disconnect the power supply. Close the filter valves before opening the steriliser.
  • Step 2: Unscrew the upper housing. Remove the lamp assembly carefully.
  • Step 3: Withdraw the quartz sleeve. Inspect it for mineral deposits. Clean only with a soft cloth.
  • Step 4: Remove the UV-C lamp from the socket. Install a genuine LGND Eclipse Internal UV-C™ Replacement Lamp of the correct wattage (3W or 5W). Avoid touching the glass with bare fingers.
  • Step 5: Reinstall the quartz sleeve. Check that the O-ring is correctly positioned. Lubricate with aquarium-safe silicone grease if necessary.
  • Step 6: Reassemble the housing. Restore power and inspect carefully for correct operation.
FAQ ›
What does the Eclipse Internal UV-C™ do?
It helps reduce suspended algae and microorganisms, improving aquarium water clarity.
Will it eliminate green water?
Yes. UV-C treatment is effective against free-floating algae responsible for green water.
Does it remove algae from aquarium glass or decorations?
No. UV-C only affects microorganisms passing through the sterilisation chamber.
Will UV-C harm beneficial bacteria?
Most beneficial nitrifying bacteria remain attached to filter media and aquarium surfaces. UV-C primarily affects microorganisms circulating through the chamber.
Can it be used in planted aquariums?
Yes. The enclosed UV-C chamber prevents direct ultraviolet exposure to aquatic plants.
Does the steriliser have a built-in timer?
Yes. The timer provides 3, 6, 12 and 24-hour operating modes, allowing automatic daily operation.
Can the water flow be adjusted?
Yes. The integrated pump features adjustable water flow.
Can it operate continuously?
Yes. The 24-hour mode provides continuous UV-C operation when the unit is correctly installed and water circulation is maintained.
Can it replace my aquarium filter?
No. UV-C sterilisation complements conventional mechanical and biological filtration but does not replace it.
Is the UV-C lamp replaceable?
Yes. The UV-C lamp is replaceable. For optimum sterilisation performance, replace the lamp every 6–12 months, depending on operating time and water conditions. Always use a genuine LGND Eclipse Internal UV-C™ replacement lamp.
Safety ›

Download Safety Data Sheet (SDS)

Important Safety Instructions

  • ⚠ Disconnect the power supply before servicing.
  • ⚠ Never operate the UV-C lamp outside the housing.
  • ⚠ Never look directly at an illuminated UV-C lamp.
  • ⚠ UV-C radiation can cause serious eye and skin injury.
  • ⚠ Do not expose fish, animals or people directly to UV-C radiation.
  • ⚠ Handle the quartz sleeve with care.
  • ⚠ Replace any cracked or damaged quartz sleeve immediately.
  • ⚠ Keep all electrical connections dry.
  • ⚠ Ensure hose fittings are fully secured before operation.
  • ⚠ Always inspect for leaks after maintenance.
  • ⚠ This appliance is intended for indoor aquarium use only.
  • ⚠ Keep out of reach of children.
Download Images ›
Code Name
220181 LGND Eclipse Internal UV‑C 3W
220181 LGND Eclipse Internal UV‑C 3W Package
220182 LGND Eclipse Internal UV‑C 5W
220182 LGND Eclipse Internal UV‑C 5W Package